Edwards EST Red Call Point

Manual Call Point | Edwards EST Red Call Point

Edwards EST Red Call Point

5 (0 Reviews) | In Stock (Ready to Ship)
₹ 3,190.00 ₹ 3,450.00 Save 8%

+ GST extra as applicable

The Edwards EST Red Call Point is a manual fire alarm initiation device designed to allow occupants to manually activate a fire alarm system during a fire emergency. Edwards EST manual pull stations are available in different configurations within the Signature Series, including single-action, presignal and double-action models.

The red, highly visible design helps users identify the manual fire alarm station quickly during an emergency. Depending on the selected model, the station may use a traditional pull-handle arrangement or a contemporary double-action design.


100% Genuine

Secure Checkout

Fast Delivery

Edwards EST Red Call Point

The Edwards EST Red Call Point is a manual fire alarm initiation device designed to allow occupants to manually activate a fire alarm system during a fire emergency. Edwards EST manual pull stations are available in different configurations within the Signature Series, including single-action, presignal and double-action models.

The red, highly visible design helps users identify the manual fire alarm station quickly during an emergency. Depending on the selected model, the station may use a traditional pull-handle arrangement or a contemporary double-action design.

Key Features

  • Edwards EST fire alarm manual call point
  • Red, highly visible housing
  • Available in different Signature Series configurations
  • Single-action and double-action options, depending on model
  • Addressable Signature Series operation for applicable models
  • Electronic addressing and intelligent communication on compatible systems
  • Suitable for manual fire alarm initiation
  • Available for different fire alarm system requirements
  • Suitable for commercial, industrial and institutional applications
  • Designed for installation by qualified fire alarm professionals

What Is an Edwards EST Red Call Point?

An Edwards EST Red Call Point, also commonly called a manual pull station or manual fire alarm station, allows a person to manually initiate a fire alarm when a fire or other emergency condition is observed.

Edwards' Signature Series manual pull stations include the SIGA-270, SIGA-270P and SIGA-278 models. The SIGA-270 family uses the familiar teardrop-style design, while the SIGA-278 uses a contemporary design with a red Lexan housing and double-action operation.

Edwards EST Manual Call Point Models

Model

General Configuration

Housing / Design

Operation

SIGA-270

Signature Series manual pull station

Die-cast zinc, red finish

Single action

SIGA-270P

Presignal manual pull station

Die-cast zinc, red finish

Presignal / two-stage application

SIGA-278

Signature Series manual pull station

Red Lexan

Double action, single stage

The exact functionality, installation requirements and system compatibility should be verified against the specific model selected.

Edwards SIGA-270 Red Call Point

The SIGA-270 features Edwards' traditional teardrop-style manual pull-station design. Edwards documentation describes the station as being made from die-cast zinc with a red epoxy powder-coat finish and aluminum-coloured stripes and markings.

The single-action mechanism is activated by pulling the handle, which breaks the glass rod and initiates the alarm condition.

The SIGA-270 is part of the Edwards Signature Series and is intended for compatible Signature Series fire alarm systems.

Edwards SIGA-278 Red Call Point

The SIGA-278 is the contemporary-style manual station in the Edwards Signature Series range. It uses a durable red-coloured Lexan housing.

Its double-action operation requires the user to first lift the upper door and then pull the alarm handle. This two-step operation can help reduce accidental activation in suitable applications.

Edwards SIGA-270P Presignal Call Point

The SIGA-270P is a presignal version designed for applications requiring two-stage operation. Edwards documentation identifies a general alarm key switch for this configuration.

The exact fire alarm sequence and system response depend on the fire alarm control panel programming and project configuration.

How Does an Edwards EST Call Point Work?

A manual call point provides a direct way for a person to initiate a fire alarm.

In a typical sequence:

  1. A person identifies a fire or emergency condition.
  2. The manual call point is operated.
  3. The call point sends its alarm signal to the compatible fire alarm system.
  4. The fire alarm control panel identifies the activated device according to the system configuration.
  5. Configured notification appliances and other programmed outputs respond.
  6. Building emergency procedures can then be initiated.

For an addressable Signature Series installation, the manual station communicates with the compatible Signature system and can be individually identified by the fire alarm control system.

Addressable Edwards EST Call Point

The Edwards Signature Series includes intelligent manual pull stations. Edwards describes these intelligent pull stations as devices with integral microprocessors that improve communication and fire alarm control-panel response.

This makes the correct system compatibility particularly important. A Signature Series manual station should not be treated as a universal manual call point for every conventional or addressable fire alarm panel.

Technical Specifications

Because “Edwards EST Red Call Point” refers to a product family rather than one unique model, exact technical specifications should be confirmed from the model number.

Specification

Details

Product Type

Manual Fire Alarm Call Point / Pull Station

Brand

Edwards / EST

Series

Signature Series, for applicable models

Colour

Red

Models

SIGA-270, SIGA-270P, SIGA-278 and applicable variants

System Type

Intelligent/addressable for Signature Series models

Activation

Single action, presignal or double action depending on model

Housing

Model dependent

Communication

Edwards Signature system, where applicable

Addressing

Electronic addressing for applicable intelligent models

Mounting

Model and installation configuration dependent

Operating Voltage

Model/system dependent

Operating Temperature

Model dependent

Humidity

Model dependent

Certifications/Listings

Model dependent

Important: Do not publish one voltage, current, IP rating or certification as a specification for every Edwards EST red call point. These values must be checked against the exact part number.

Applications

Edwards EST manual call points can be used in fire alarm installations across:

  • Commercial buildings
  • Offices
  • Hotels
  • Hospitals
  • Schools and educational facilities
  • Shopping centres
  • Warehouses
  • Manufacturing facilities
  • Industrial buildings
  • Public buildings
  • Institutional facilities

Manual call points are generally positioned at accessible locations where occupants can quickly operate them during an emergency, subject to the applicable fire alarm design and local requirements.

Edwards EST Call Point Compatibility

Compatibility is one of the most important factors when selecting an Edwards EST manual call point.

Before ordering, verify:

  • Exact model number
  • Existing fire alarm control panel
  • Conventional or intelligent system
  • Signature Series compatibility
  • Required mounting arrangement
  • Single-action or double-action requirement
  • Presignal/two-stage requirements
  • Required approvals
  • Replacement compatibility with the existing device

Edwards maintains separate conventional and intelligent initiation product ranges, so the phrase “Edwards call point” alone is not sufficient to establish system compatibility.

Red Manual Call Point for Fire Alarm Systems

The red colour and manual activation mechanism make the Edwards EST call point readily identifiable as a fire alarm initiation device.

For projects using Edwards Signature intelligent systems, selecting the correct Signature manual station can provide integration with the intelligent fire alarm architecture. Edwards states that its Signature manual pull stations are available in both single-action and double-action formats.

Installation Considerations

A manual call point should be installed according to the manufacturer's installation instructions, approved fire alarm design and applicable local codes.

Important considerations include:

  • Correct mounting height
  • Accessibility
  • Clear visibility
  • Suitable location along evacuation routes
  • Correct electrical wiring
  • Correct fire alarm panel compatibility
  • Proper device addressing where applicable
  • Testing after installation
  • Appropriate identification/signage where required

Installation and commissioning should be carried out by appropriately qualified fire alarm personnel.

Why Choose Edwards EST Red Call Point?

Edwards provides a range of manual fire alarm initiation devices for conventional and intelligent fire safety systems. The Signature Series offers different manual station configurations to meet different operational requirements, including traditional single-action, presignal and double-action options.

For replacement projects, identifying the exact existing Edwards model is important because visually similar manual stations can have different operating mechanisms and system compatibility.

Frequently Asked Questions

What is an Edwards EST Red Call Point?

An Edwards EST Red Call Point is a manual fire alarm initiation device that allows an occupant to manually activate a compatible fire alarm system during an emergency.

Is Edwards EST call point addressable?

The Signature Series manual pull stations, including models such as SIGA-270 and SIGA-278, are designed for intelligent/addressable Signature Series systems. The exact model and system compatibility should be verified before installation.

What is the difference between SIGA-270 and SIGA-278?

The SIGA-270 uses Edwards' traditional teardrop-style design and single-action pull operation. The SIGA-278 is a contemporary-style red Lexan station with double-action operation.

What is SIGA-270P?

SIGA-270P is a presignal version of the Edwards manual pull station intended for applications requiring two-stage operation. Edwards identifies a general alarm key switch as part of this configuration.

Is the Edwards EST call point suitable for conventional fire alarm systems?

Edwards offers both conventional manual initiation devices and intelligent Signature Series devices. The exact call point must therefore be matched to the fire alarm control panel and system architecture.

Is SIGA-278 single action or double action?

The SIGA-278 is a double-action, single-stage manual station. The user first lifts the upper door and then pulls the alarm handle.

Why are fire alarm call points usually red?

Red provides high visual recognition for fire alarm equipment and helps occupants quickly identify the manual alarm initiation point during an emergency. The exact colour and marking requirements should follow the applicable local standards and project specification.

Can an Edwards EST call point work with any fire alarm panel?

No. Edwards manual stations are system-specific. Signature Series intelligent manual stations should be used with compatible Signature architecture, while conventional products require compatible conventional fire alarm systems.

How do I select the correct Edwards EST red call point?

First identify the existing fire alarm control panel and the exact existing call-point model. Then select the required operation—single action, double action or presignal—and verify electrical, mounting and approval requirements.

Buy Edwards EST Red Call Point

Looking for an Edwards EST Red Call Point / Manual Pull Station for a new installation or replacement requirement?

DNG Fire Engineering can assist with product identification and supply based on your fire alarm system requirements.

For the most accurate selection, share the existing Edwards model number or a clear product photograph, along with the fire alarm control panel model.

Request a Quote for Edwards EST Red Call Point

For replacement projects, matching the existing model and system compatibility is recommended before placing an order.

 

 

Shipping Policy

Dispatch Time: Orders are typically processed and dispatched within 24-48 working hours upon successful payment confirmation via our secure gateway.

Delivery: We offer Pan-India delivery via secure logistics partners. Transit time is generally 3-7 business days depending on the location.

Return Policy

Returns: Defective items can be returned or exchanged within 7 days of delivery subject to our standard inspection and return policy. Please contact our support team to initiate a return request.

Add-Ons

Related Products

Bosch Avenar Panel 2000
Bosch Avenar Panel 2000
₹ 159,000.00
View Details
Bosch FPA-1000-V2 Addressable Fire Panel-UL
Bosch FPA-1000-V2 Addressable Fire Panel-UL
₹ 98,000.00
View Details
Conventional Manual Call Point
Conventional Manual Call Point
₹ 1,789.00
View Details
Edwards EST Manual Call Point
Edwards EST Manual Call Point
₹ 3,900.00
View Details