Edwards EST Manual Call Point

Manual Call Point | Edwards EST Manual Call Point

Edwards EST Manual Call Point

5 (0 Reviews) | In Stock (Ready to Ship)
₹ 3,900.00 ₹ 4,500.00 Save 13%

+ GST extra as applicable

The Edwards EST Manual Call Point is a manual fire alarm initiating device designed to allow occupants to manually activate an alarm during a fire or emergency.

Edwards EST Signature Series manual pull stations include the SIGA-270, SIGA-270P and SIGA-278 models. These devices are designed as intelligent/addressable initiating devices and communicate with compatible Edwards EST Signature Series fire alarm systems.

Manual call points are typically positioned along escape routes, near exits and at other accessible locations where occupants can quickly raise an alarm after discovering a fire.


100% Genuine

Secure Checkout

Fast Delivery

Edwards EST Manual Call Point

The Edwards EST Manual Call Point is a manual fire alarm initiating device designed to allow occupants to manually activate an alarm during a fire or emergency.

Edwards EST Signature Series manual pull stations include the SIGA-270, SIGA-270P and SIGA-278 models. These devices are designed as intelligent/addressable initiating devices and communicate with compatible Edwards EST Signature Series fire alarm systems.

Manual call points are typically positioned along escape routes, near exits and at other accessible locations where occupants can quickly raise an alarm after discovering a fire.

Key Features

  • Edwards EST Signature Series manual pull station
  • Addressable/intelligent fire alarm initiating device
  • Available in single-action and double-action configurations
  • SIGA-270 uses positive pull-lever operation
  • SIGA-270P provides presignal/two-stage functionality
  • SIGA-278 uses double-action operation
  • Integral microprocessor
  • Electronic addressing
  • Non-volatile address memory
  • Highly visible red construction
  • Self-diagnostic capability
  • Designed for compatible EST Signature Series systems
  • Available with recognized fire safety approvals for applicable models

What Is an Edwards EST Manual Call Point?

An Edwards EST Manual Call Point, also called an EST manual pull station, is a manually operated fire alarm initiating device.

When a person discovers a fire, they can operate the manual call point instead of waiting for an automatic smoke or heat detector. The device communicates the alarm condition to the compatible fire alarm control panel.

Unlike a conventional manual call point, an addressable EST Signature Series manual pull station can be individually identified by the fire alarm system.

The Signature Series design incorporates an integral microprocessor, while electronic addressing allows the loop controller to identify the individual manual station.

Edwards EST Manual Call Point Models

Model

Operating Type

Application

SIGA-270

Single-action

One-stage manual alarm initiation

SIGA-270P

Presignal / two-stage

Applications requiring general alarm keyswitch operation

SIGA-278

Double-action, single-stage

Lift upper door, then operate alarm handle

The SIGA-270 has the familiar teardrop-shaped design with a visible glass rod and positive pull-lever operation. The SIGA-278 uses a contemporary red Lexan design and requires the user to lift the upper door before pulling the alarm handle.

SIGA-270 Manual Call Point

The Edwards SIGA-270 is a single-action manual pull station from the EST Signature Series.

Its pull-lever mechanism is designed so that one pull activates the alarm. The unit uses a visible glass rod, while the manufacturer documentation notes that the glass rod is not required for the station to operate. Its housing is made from die-cast zinc with a red epoxy powder-coat finish and contrasting markings.

SIGA-270 Highlights

  • Single-action operation
  • Break-glass design
  • Positive pull-lever operation
  • Red die-cast zinc housing
  • Integral microprocessor
  • Electronic addressing
  • Non-volatile memory
  • Signature Series compatibility
  • Self-diagnostic operation

SIGA-270P Presignal Manual Call Point

The SIGA-270P is intended for applications requiring two-stage alarm operation.

It incorporates a general alarm (GA) keyswitch for applications where a presignal arrangement is required.

The exact fire alarm sequence should always be configured according to the project design and the compatible EST fire alarm control panel.

SIGA-278 Manual Call Point

The SIGA-278 is a double-action, single-stage manual pull station.

To initiate an alarm, the upper door is first lifted and then the alarm handle is pulled. The station uses a durable red Lexan construction and provides a different operating format from the SIGA-270.

Technical Specifications

Because “Edwards EST Manual Call Point” covers multiple models, the exact specifications should be published against the individual part number.

Specification

Edwards EST Manual Call Point

Product Type

Addressable Manual Pull Station

Product Family

EST Signature Series

Models

SIGA-270, SIGA-270P, SIGA-278

System Type

Intelligent / Addressable

SIGA-270 Operation

Single-action

SIGA-270P Operation

Presignal / two-stage

SIGA-278 Operation

Double-action, single-stage

Housing

Model-dependent; SIGA-270 uses die-cast zinc

Colour

Red

Addressing

Electronic

Processing

Integral microprocessor

Address Memory

Non-volatile

Communication

Signature Series addressable loop

Testing

Tool/key-based depending on model

Approvals

Model/market dependent

Operating Voltage

Verify exact model datasheet

Current Consumption

Verify exact model datasheet

Dimensions

Verify exact model datasheet

Operating Temperature

Verify exact model datasheet

Important: Do not publish generic 230V specifications for this product. The EST Signature Series manual pull stations are low-voltage addressable fire alarm devices; third-party listings sometimes contain incorrect or mixed specifications. The manufacturer's documentation should be used for the exact model.

How Does an Edwards EST Manual Call Point Work?

The basic sequence is:

Fire discovered → Manual call point operated → Device reports alarm → EST fire alarm control panel identifies device → Alarm sequence initiated → Notification devices operate

Because the Signature Series manual station contains an integral microprocessor and electronic addressing, the compatible control panel can identify the initiating device rather than simply receiving a conventional zone-level alarm.

Edwards EST Manual Call Point vs Conventional MCP

Feature

Edwards EST Manual Call Point

Conventional Manual Call Point

System

Addressable

Conventional

Individual identification

Yes, compatible Signature system

Normally zone-level

Device addressing

Electronic

Normally not individually addressed

Communication

Addressable loop

Conventional detection zone

Microprocessor

Integral in Signature Series

Model-dependent

Panel compatibility

Compatible EST Signature system

Compatible conventional panel

Alarm location

Individual device

Zone

Selection

Must match EST system

Must match conventional panel

Do not connect an EST Signature Series manual pull station to a conventional fire alarm panel simply because both products are called manual call points. System compatibility is essential.

Applications

Edwards EST Manual Call Points can be used in a variety of addressable fire alarm installations, including:

  • Commercial buildings
  • Office buildings
  • Hotels
  • Hospitals
  • Schools and educational facilities
  • Shopping centres
  • Warehouses
  • Manufacturing facilities
  • Industrial buildings
  • Institutional buildings
  • Airports and transportation facilities
  • Large commercial complexes

The appropriate model should be selected according to the fire alarm design, operating requirements and compatible EST control panel.

Installation Considerations

Before installing an Edwards EST Manual Call Point, verify:

  1. Exact model number.
  2. Compatible EST fire alarm control panel.
  3. Signature Series loop compatibility.
  4. Approved mounting arrangement.
  5. Correct wiring and terminal configuration.
  6. Required address configuration.
  7. Local fire alarm code requirements.
  8. Accessibility along the designated escape route.
  9. Correct testing and reset procedure.

The manufacturer documentation states that terminals accommodate #12 to #18 AWG (2.5 to 0.75 mm²) wire, and recommends installation according to the latest applicable national and local fire alarm codes.

Testing & Maintenance

Manual call points should be regularly inspected and tested as part of the fire alarm system maintenance program.

Typical checks include:

  • Visual inspection
  • Physical condition of the housing
  • Accessibility of the device
  • Operation of the manual mechanism
  • Alarm communication to the panel
  • Correct device identification
  • Trouble/self-diagnostic status
  • Reset operation
  • Wiring and terminal inspection

For the SIGA-270 series, the manufacturer's documentation describes opening the station with a tool and operating the exposed switch for testing/reset; the SIGA-278 uses the supplied key. The devices also perform automatic self-diagnosis and can report a trouble condition when a fault is detected.

Why Choose Edwards EST Manual Call Point?

The Edwards EST Signature Series manual pull station range combines manual fire alarm activation with intelligent addressable communication.

Key benefits include:

  • Individual device identification
  • Intelligent device electronics
  • Electronic addressing
  • Multiple operating configurations
  • Robust manual activation mechanism
  • Self-diagnostic functionality
  • Compatibility with EST Signature Series systems
  • Suitable for large and complex addressable fire alarm installations

Frequently Asked Questions

Is the Edwards EST Manual Call Point addressable?

Yes. The SIGA-270, SIGA-270P and SIGA-278 are Signature Series intelligent/addressable manual pull stations.

What is the difference between SIGA-270 and SIGA-278?

The SIGA-270 uses a single-action pull-lever mechanism with a visible glass rod, while the SIGA-278 uses a double-action design requiring the upper door to be lifted before the alarm handle is pulled.

What is SIGA-270P?

SIGA-270P is a presignal version equipped with a general alarm keyswitch for applications requiring two-stage operation.

Is Edwards EST Manual Call Point conventional or addressable?

The commonly referenced SIGA-270/SIGA-270P/SIGA-278 range is addressable/intelligent and belongs to the EST Signature Series.

Can SIGA-270 work with any fire alarm panel?

No. It should be used with a compatible Edwards EST Signature Series system. Fire alarm devices should always be selected according to the control panel's approved device compatibility.

Does SIGA-270 have a glass element?

Yes. The SIGA-270 uses a visible glass rod as part of its break-glass design. The manufacturer documentation also notes that the glass rod is not required for the station to operate.

Is SIGA-278 single action?

No. SIGA-278 is a double-action, single-stage manual pull station. The upper door is lifted first and the alarm handle is then pulled.

How do you reset an Edwards EST manual call point?

The reset procedure depends on the exact model. The manufacturer's documentation specifies tool-based opening/reset for SIGA-270 series stations and a supplied key for SIGA-278.

 

Shipping Policy

Dispatch Time: Orders are typically processed and dispatched within 24-48 working hours upon successful payment confirmation via our secure gateway.

Delivery: We offer Pan-India delivery via secure logistics partners. Transit time is generally 3-7 business days depending on the location.

Return Policy

Returns: Defective items can be returned or exchanged within 7 days of delivery subject to our standard inspection and return policy. Please contact our support team to initiate a return request.

Add-Ons

Related Products

Bosch Avenar Panel 2000
Bosch Avenar Panel 2000
₹ 159,000.00
View Details
Bosch FPA-1000-V2 Addressable Fire Panel-UL
Bosch FPA-1000-V2 Addressable Fire Panel-UL
₹ 98,000.00
View Details
Conventional Manual Call Point
Conventional Manual Call Point
₹ 1,789.00
View Details
Edwards EST Red Call Point
Edwards EST Red Call Point
₹ 3,190.00
View Details