Manual Call Point | Edwards EST Manual Call Point
+ GST extra as applicable
The Edwards EST Manual Call Point is a manual fire alarm initiating device designed to allow occupants to manually activate an alarm during a fire or emergency.
Edwards EST Signature Series manual pull stations include the SIGA-270, SIGA-270P and SIGA-278 models. These devices are designed as intelligent/addressable initiating devices and communicate with compatible Edwards EST Signature Series fire alarm systems.
Manual call points are typically positioned along escape routes, near exits and at other accessible locations where occupants can quickly raise an alarm after discovering a fire.
100% Genuine
Secure Checkout
Fast Delivery
The Edwards EST Manual Call Point is a manual fire alarm initiating device designed to allow occupants to manually activate an alarm during a fire or emergency.
Edwards EST Signature Series manual pull stations include the SIGA-270, SIGA-270P and SIGA-278 models. These devices are designed as intelligent/addressable initiating devices and communicate with compatible Edwards EST Signature Series fire alarm systems.
Manual call points are typically positioned along escape routes, near exits and at other accessible locations where occupants can quickly raise an alarm after discovering a fire.
An Edwards EST Manual Call Point, also called an EST manual pull station, is a manually operated fire alarm initiating device.
When a person discovers a fire, they can operate the manual call point instead of waiting for an automatic smoke or heat detector. The device communicates the alarm condition to the compatible fire alarm control panel.
Unlike a conventional manual call point, an addressable EST Signature Series manual pull station can be individually identified by the fire alarm system.
The Signature Series design incorporates an integral microprocessor, while electronic addressing allows the loop controller to identify the individual manual station.
|
Model |
Operating Type |
Application |
|
SIGA-270 |
Single-action |
One-stage manual alarm initiation |
|
SIGA-270P |
Presignal / two-stage |
Applications requiring general alarm keyswitch operation |
|
SIGA-278 |
Double-action, single-stage |
Lift upper door, then operate alarm handle |
The SIGA-270 has the familiar teardrop-shaped design with a visible glass rod and positive pull-lever operation. The SIGA-278 uses a contemporary red Lexan design and requires the user to lift the upper door before pulling the alarm handle.
The Edwards SIGA-270 is a single-action manual pull station from the EST Signature Series.
Its pull-lever mechanism is designed so that one pull activates the alarm. The unit uses a visible glass rod, while the manufacturer documentation notes that the glass rod is not required for the station to operate. Its housing is made from die-cast zinc with a red epoxy powder-coat finish and contrasting markings.
The SIGA-270P is intended for applications requiring two-stage alarm operation.
It incorporates a general alarm (GA) keyswitch for applications where a presignal arrangement is required.
The exact fire alarm sequence should always be configured according to the project design and the compatible EST fire alarm control panel.
The SIGA-278 is a double-action, single-stage manual pull station.
To initiate an alarm, the upper door is first lifted and then the alarm handle is pulled. The station uses a durable red Lexan construction and provides a different operating format from the SIGA-270.
Because “Edwards EST Manual Call Point” covers multiple models, the exact specifications should be published against the individual part number.
|
Specification |
Edwards EST Manual Call Point |
|
Product Type |
Addressable Manual Pull Station |
|
Product Family |
EST Signature Series |
|
Models |
SIGA-270, SIGA-270P, SIGA-278 |
|
System Type |
Intelligent / Addressable |
|
SIGA-270 Operation |
Single-action |
|
SIGA-270P Operation |
Presignal / two-stage |
|
SIGA-278 Operation |
Double-action, single-stage |
|
Housing |
Model-dependent; SIGA-270 uses die-cast zinc |
|
Colour |
Red |
|
Addressing |
Electronic |
|
Processing |
Integral microprocessor |
|
Address Memory |
Non-volatile |
|
Communication |
Signature Series addressable loop |
|
Testing |
Tool/key-based depending on model |
|
Approvals |
Model/market dependent |
|
Operating Voltage |
Verify exact model datasheet |
|
Current Consumption |
Verify exact model datasheet |
|
Dimensions |
Verify exact model datasheet |
|
Operating Temperature |
Verify exact model datasheet |
Important: Do not publish generic 230V specifications for this product. The EST Signature Series manual pull stations are low-voltage addressable fire alarm devices; third-party listings sometimes contain incorrect or mixed specifications. The manufacturer's documentation should be used for the exact model.
The basic sequence is:
Fire discovered → Manual call point operated → Device reports alarm → EST fire alarm control panel identifies device → Alarm sequence initiated → Notification devices operate
Because the Signature Series manual station contains an integral microprocessor and electronic addressing, the compatible control panel can identify the initiating device rather than simply receiving a conventional zone-level alarm.
|
Feature |
Edwards EST Manual Call Point |
Conventional Manual Call Point |
|
System |
Addressable |
Conventional |
|
Individual identification |
Yes, compatible Signature system |
Normally zone-level |
|
Device addressing |
Electronic |
Normally not individually addressed |
|
Communication |
Addressable loop |
Conventional detection zone |
|
Microprocessor |
Integral in Signature Series |
Model-dependent |
|
Panel compatibility |
Compatible EST Signature system |
Compatible conventional panel |
|
Alarm location |
Individual device |
Zone |
|
Selection |
Must match EST system |
Must match conventional panel |
Do not connect an EST Signature Series manual pull station to a conventional fire alarm panel simply because both products are called manual call points. System compatibility is essential.
Edwards EST Manual Call Points can be used in a variety of addressable fire alarm installations, including:
The appropriate model should be selected according to the fire alarm design, operating requirements and compatible EST control panel.
Before installing an Edwards EST Manual Call Point, verify:
The manufacturer documentation states that terminals accommodate #12 to #18 AWG (2.5 to 0.75 mm²) wire, and recommends installation according to the latest applicable national and local fire alarm codes.
Manual call points should be regularly inspected and tested as part of the fire alarm system maintenance program.
Typical checks include:
For the SIGA-270 series, the manufacturer's documentation describes opening the station with a tool and operating the exposed switch for testing/reset; the SIGA-278 uses the supplied key. The devices also perform automatic self-diagnosis and can report a trouble condition when a fault is detected.
The Edwards EST Signature Series manual pull station range combines manual fire alarm activation with intelligent addressable communication.
Key benefits include:
Yes. The SIGA-270, SIGA-270P and SIGA-278 are Signature Series intelligent/addressable manual pull stations.
The SIGA-270 uses a single-action pull-lever mechanism with a visible glass rod, while the SIGA-278 uses a double-action design requiring the upper door to be lifted before the alarm handle is pulled.
SIGA-270P is a presignal version equipped with a general alarm keyswitch for applications requiring two-stage operation.
The commonly referenced SIGA-270/SIGA-270P/SIGA-278 range is addressable/intelligent and belongs to the EST Signature Series.
No. It should be used with a compatible Edwards EST Signature Series system. Fire alarm devices should always be selected according to the control panel's approved device compatibility.
Yes. The SIGA-270 uses a visible glass rod as part of its break-glass design. The manufacturer documentation also notes that the glass rod is not required for the station to operate.
No. SIGA-278 is a double-action, single-stage manual pull station. The upper door is lifted first and the alarm handle is then pulled.
The reset procedure depends on the exact model. The manufacturer's documentation specifies tool-based opening/reset for SIGA-270 series stations and a supplied key for SIGA-278.
Dispatch Time: Orders are typically processed and dispatched within 24-48 working hours upon successful payment confirmation via our secure gateway.
Delivery: We offer Pan-India delivery via secure logistics partners. Transit time is generally 3-7 business days depending on the location.
Returns: Defective items can be returned or exchanged within 7 days of delivery subject to our standard inspection and return policy. Please contact our support team to initiate a return request.