Bosch FPA-1000-V2 Addressable Fire Panel-UL

Manual Call Point | Bosch FPA-1000-V2 Addressable Fire Panel-UL

Bosch FPA-1000-V2 Addressable Fire Panel-UL

5 (0 Reviews) | In Stock (Ready to Ship)
₹ 98,000.00 ₹ 110,000.00 Save 11%

+ GST extra as applicable

The Bosch FPA-1000-V2 Addressable Fire Panel is an analog addressable fire alarm control panel designed for small to medium-sized residential, commercial and public-building applications. The panel combines fire alarm control functions, Signaling Line Circuit (SLC), Notification Appliance Circuits (NAC), relays, power supply, Digital Alarm Communicator Transmitter (DACT) and Ethernet connectivity in a single system platform.

The standard FPA-1000-V2 configuration includes one FPE-1000-SLC module supporting up to 254 addressable points. A second SLC module can expand the panel to 508 addressable points across two loops.

Product status: Bosch/Keenfinity currently lists FPA-1000-V2 as Discontinued. It can therefore be relevant for replacement, retrofit and existing-system requirements, subject to product availability and system compatibility.


100% Genuine

Secure Checkout

Fast Delivery

Bosch FPA-1000-V2 Addressable Fire Panel – UL

The Bosch FPA-1000-V2 Addressable Fire Panel is an analog addressable fire alarm control panel designed for small to medium-sized residential, commercial and public-building applications. The panel combines fire alarm control functions, Signaling Line Circuit (SLC), Notification Appliance Circuits (NAC), relays, power supply, Digital Alarm Communicator Transmitter (DACT) and Ethernet connectivity in a single system platform.

The standard FPA-1000-V2 configuration includes one FPE-1000-SLC module supporting up to 254 addressable points. A second SLC module can expand the panel to 508 addressable points across two loops.

Product status: Bosch/Keenfinity currently lists FPA-1000-V2 as Discontinued. It can therefore be relevant for replacement, retrofit and existing-system requirements, subject to product availability and system compatibility.

Key Features

  • Analog addressable fire alarm control panel
  • Up to 254 addressable points on one SLC
  • Expandable up to 508 addressable points on two SLCs
  • Two onboard Notification Appliance Circuits
  • Built-in Ethernet connection
  • Browser-based programming and diagnostics
  • Conettix Alarm-over-IP communication support
  • Dual-line PSTN DACT
  • Peer-to-peer networking capability for up to eight V2 panels
  • 4-line × 20-character alphanumeric LCD
  • Built-in keypad for system control and programming
  • Fire, gas alarm, power, supervisory, silence and trouble LED indications
  • Surface or semi-flush mounting options
  • Compatible with selected Bosch analog addressable detectors and modules

What Is Bosch FPA-1000-V2?

The FPA-1000-V2 is an analog addressable Fire Alarm Control Panel (FACP). It communicates with compatible addressable detectors and modules through its Signaling Line Circuit.

In its standard configuration, the panel contains one SLC module. The system can be expanded by installing a second FPE-1000-SLC module, increasing the supported addressable point capacity from 254 to 508.

This makes the FPA-1000-V2 suitable for projects where individual device identification and addressable fire detection are required.

Bosch FPA-1000-V2 Technical Specifications

Specification

Bosch FPA-1000-V2

Product Type

Analog Addressable Fire Alarm Control Panel

Model

FPA-1000-V2

Brand

Bosch

SLC Configuration

1 standard SLC; expandable to 2

Addressable Point Capacity

Up to 254 points per SLC

Maximum Addressable Points

Up to 508 with two SLCs

SLC Wiring

Class B Style 4 or Class A Style 6/7

SLC Voltage

Nominal 39 VDC

SLC Current

204 mA per FPE-1000-SLC

NACs

2 onboard NACs

NAC Configuration

Class A or Class B

NAC Voltage

Nominal 24 V FWR

NAC Current

Up to 2.5 A per NAC, subject to overall limitations

Display

4-line × 20-character alphanumeric LCD

Keypad

Built-in alphanumeric keypad

Ethernet

Built-in RJ45 Ethernet interface

DACT

Dual-line PSTN DACT

Networking

Peer-to-peer networking with compatible networking card

Auxiliary Power

Two auxiliary power supplies

Enclosure

Cold-rolled steel

Enclosure Colour

Red

Mounting

Surface or semi-flush

Enclosure Dimensions

Approx. 57.7 × 36.8 × 10.9 cm

Enclosure Weight

Approx. 8.32 kg

Certification/Listing

UL-listed system applications; additional approvals depend on configuration/market

Product Status

Discontinued

The technical documentation specifies 254 addresses per loop and a maximum of 508 addresses for the two-loop configuration. It also specifies two onboard NACs and the panel's Ethernet and DACT interfaces.

1 Loop or 2 Loop Configuration

One important SEO/product-detail point is that FPA-1000-V2 should not be described only as a fixed 2-loop panel.

The standard panel includes one FPE-1000-SLC, supporting up to 254 addressable points. A second FPE-1000-SLC can be added to provide a total of two SLCs and up to 508 addressable points.

This configuration can be useful when the system needs additional addressable capacity without replacing the complete control panel.

Addressable Device Capacity

The FPA-1000-V2 supports up to 254 addressable points per SLC. With two SLC modules installed, the panel can support up to 508 addressable points.

However, the actual number of detectors and modules in a project should not be calculated from the maximum address count alone. Device compatibility, current consumption, wiring length, loop loading and the specific system design must also be considered.

LCD Display and User Controls

The panel incorporates a 4-line × 20-character alphanumeric LCD display for displaying programmed device and system information.

Its built-in keypad provides system control and programming functions. The documented operation keys include:

  • Acknowledge
  • Reset
  • Silence
  • Drill

The front panel also provides dedicated LED indications for fire, gas alarm, power, supervisory, silence and trouble conditions.

Ethernet Connectivity

The Bosch FPA-1000-V2 includes a built-in Ethernet interface.

The documented Ethernet functionality supports browser-based programming and diagnostics, as well as Conettix Alarm-over-IP communication. This allows suitable system configurations to support network-based communication and remote system management functions.

Networking Capability

Compatible networking cards can be used to interconnect FPA-1000-V2 panels.

Bosch documentation describes peer-to-peer networking of up to eight V2 panels in a single group. The networking architecture can therefore be used where multiple fire alarm panels need to operate as part of a coordinated system.

Notification Appliance Circuits

The FPA-1000-V2 has two onboard NACs.

The documented NAC architecture supports Class A or Class B configurations. The panel provides nominal 24 V FWR NAC power, with the available current subject to the panel's overall power limitations and system configuration.

Compatible remote NAC power supplies can also be used where additional notification circuit capacity is required. Bosch documentation identifies the FPP-RNAC-8A-4C as an optional remote NAC booster/power supply for compatible installations.

Applications

The Bosch FPA-1000-V2 can be used for addressable fire alarm applications such as:

  • Commercial buildings
  • Offices
  • Educational facilities
  • Public buildings
  • Residential applications
  • Small and medium-sized facilities
  • Industrial buildings
  • Warehouses
  • Retail premises
  • Multi-area fire detection installations
  • Retrofit and replacement projects using compatible Bosch systems

The manufacturer documentation positions the FPA-1000 family for small to medium facilities and identifies residential, commercial and public-building applications.

Installation Considerations

Installation should be performed by qualified fire alarm professionals in accordance with the applicable codes, AHJ requirements, approved drawings and Bosch installation documentation.

Important considerations include:

  • Verify compatible detectors and modules.
  • Select the appropriate SLC configuration.
  • Check loop current and wiring requirements.
  • Verify NAC loading.
  • Calculate required standby battery capacity.
  • Confirm network requirements before installing communication cards.
  • Maintain appropriate separation between SLC, NAC and other wiring where required.
  • Verify grounding and enclosure installation.
  • Program device addresses correctly.
  • Complete functional testing and commissioning after installation.

Bosch documentation specifically requires compatible UL-listed devices for UL-listed installations and emphasizes compliance with applicable codes and standards.

Maintenance

Regular inspection and testing are essential for reliable fire alarm operation.

Maintenance activities may include:

  • Checking panel power and battery status
  • Reviewing alarm, supervisory and trouble conditions
  • Testing connected detectors
  • Testing manual call points
  • Testing notification appliances
  • Inspecting SLC and NAC wiring
  • Checking communication paths
  • Reviewing event/history information
  • Verifying cause-and-effect programming
  • Testing auxiliary and relay functions
  • Maintaining service records

Maintenance frequency should follow applicable regulations, project requirements and the manufacturer's documentation.

Why Choose Bosch FPA-1000-V2?

Addressable Architecture

Individual compatible devices can be identified through the addressable SLC architecture, helping provide more precise information about alarm and fault locations.

Scalable Point Capacity

The standard one-loop configuration supports up to 254 addressable points, while the addition of a second SLC can increase the capacity to 508 points.

Integrated Connectivity

Ethernet, DACT and optional networking capabilities provide multiple communication options depending on system configuration.

Built-In Controls

The LCD display, keypad and front-panel indicators provide centralized access to system information and control functions.

Suitable for Retrofit Requirements

Because the FPA-1000-V2 is discontinued, it may be particularly relevant when maintaining or replacing equipment in an existing Bosch FPA-1000 installation. Compatibility and availability should be confirmed before purchase.

Frequently Asked Questions

What is Bosch FPA-1000-V2?

Bosch FPA-1000-V2 is an analog addressable fire alarm control panel designed for small to medium-sized fire detection applications.

How many devices can FPA-1000-V2 support?

The standard configuration supports up to 254 addressable points on one SLC. With a second FPE-1000-SLC module, the system can support up to 508 addressable points.

Is Bosch FPA-1000-V2 UL listed?

The FPA-1000 documentation identifies UL listings for applicable fire alarm control unit/system applications, including UL 864 and related listed applications. Exact listing applicability should be checked against the intended installation and configuration.

Is FPA-1000-V2 a 2-loop fire alarm panel?

It can be configured as a two-SLC system, but the standard panel includes one SLC. A second FPE-1000-SLC module is required for the two-loop/508-point configuration.

Does the FPA-1000-V2 have Ethernet?

Yes. The panel includes a built-in Ethernet connector for browser-based programming and supported Conettix Alarm-over-IP communication.

Is Bosch FPA-1000-V2 discontinued?

Yes. The current Keenfinity product listing identifies FPA-1000-V2 as discontinued. Therefore, availability should be confirmed before publishing stock-related claims or accepting an order.

Can FPA-1000-V2 be used for an existing Bosch fire alarm system?

Potentially, depending on the existing system architecture, connected devices, software/configuration and required approvals. A compatibility check should be completed before replacement or expansion.

 


Buy Bosch FPA-1000-V2 Addressable Fire Panel – UL

Looking for a Bosch FPA-1000-V2 Addressable Fire Panel for an existing Bosch fire alarm installation?

DNG Fire Engineering can assist with product identification, technical selection and replacement requirements based on the existing fire alarm system configuration.

For retrofit or replacement requirements, please provide the existing panel model, connected device types and required loop capacity so the correct compatible configuration can be confirmed.

Important: FPA-1000-V2 is currently listed as discontinued by Keenfinity. Do not publish “in stock”, “latest”, “new model” or guaranteed replacement claims unless DNG has verified current inventory and compatibility.

 

Shipping Policy

Dispatch Time: Orders are typically processed and dispatched within 24-48 working hours upon successful payment confirmation via our secure gateway.

Delivery: We offer Pan-India delivery via secure logistics partners. Transit time is generally 3-7 business days depending on the location.

Return Policy

Returns: Defective items can be returned or exchanged within 7 days of delivery subject to our standard inspection and return policy. Please contact our support team to initiate a return request.

Add-Ons

Related Products

Bosch Avenar Panel 2000
Bosch Avenar Panel 2000
₹ 159,000.00
View Details
Conventional Manual Call Point
Conventional Manual Call Point
₹ 1,789.00
View Details
Edwards EST Manual Call Point
Edwards EST Manual Call Point
₹ 3,900.00
View Details
Edwards EST Red Call Point
Edwards EST Red Call Point
₹ 3,190.00
View Details