Manual Call Point | Bosch Avenar Panel 2000
+ GST extra as applicable
Bosch AVENAR panel 2000 is a compact modular addressable fire alarm control panel designed for small to medium-sized fire detection systems. The panel combines an intelligent fire alarm controller, power supply, battery controller and LSN loop technology in a scalable platform that can be expanded according to project requirements.
The AVENAR panel 2000 is available in standard and premium license configurations and in wall-mount or frame-mount versions, making it suitable for different installation and system requirements.
100% Genuine
Secure Checkout
Fast Delivery
Bosch AVENAR panel 2000 is a compact modular addressable fire alarm control panel designed for small to medium-sized fire detection systems. The panel combines an intelligent fire alarm controller, power supply, battery controller and LSN loop technology in a scalable platform that can be expanded according to project requirements.
The AVENAR panel 2000 is available in standard and premium license configurations and in wall-mount or frame-mount versions, making it suitable for different installation and system requirements.
The AVENAR panel 2000 is an addressable fire alarm control panel used as the central control and monitoring unit of a Bosch fire detection system.
It communicates with compatible addressable fire detectors, manual call points, input/output modules and other LSN devices. Because the panel uses a modular architecture, the system can be configured according to the required number of loops and functions rather than being restricted to one fixed configuration.
A standard AVENAR panel 2000 configuration includes one LSN loop module. Bosch states that the panel can be extended with up to four additional LSN 0300 A loop modules. Each loop can accommodate up to 254 LSN elements.
|
Configuration |
LSN Loops |
Maximum LSN Elements* |
|
Standard configuration |
1 |
Up to 254 |
|
With 1 additional loop module |
2 |
Up to 508 |
|
With 2 additional loop modules |
3 |
Up to 762 |
|
With 3 additional loop modules |
4 |
Up to 1,016 |
|
With 4 additional loop modules |
5 |
Up to 1,270 |
*The figures above are a theoretical calculation based on Bosch's stated maximum of 254 LSN elements per loop. Actual system design depends on device types, power requirements, topology and applicable system limitations.
Important SEO point: Don't title every AVENAR panel 2000 as a “5 Loop Panel.” The actual supplied configuration must be specified by the exact panel kit and installed modules.
|
Specification |
Bosch AVENAR Panel 2000 |
|
Product family |
AVENAR panel |
|
Product type |
Modular addressable fire alarm control panel |
|
Application |
Small to medium-sized fire detection systems |
|
Standard loop configuration |
1 LSN loop |
|
Expansion |
Up to 4 additional LSN 0300 A loop modules |
|
Maximum loops with specified expansion |
Up to 5 |
|
Elements per LSN loop |
Up to 254 |
|
Display |
7-inch colour WVGA, 800 × 480 pixels |
|
Operating controls |
6 keys and 18 LEDs |
|
Networking |
Ethernet / CAN bus options depending on configuration |
|
Housing |
Sheet steel |
|
Protection category |
IP30 |
|
Operating temperature |
-5°C to +50°C |
|
Storage temperature |
-20°C to +60°C |
|
Relative humidity |
Maximum 95%, non-condensing at 25°C |
|
Wall-mount battery |
12 V, 24–27 Ah |
|
Frame-mount battery |
12 V, 38–45 Ah |
|
Wall-mount configuration |
Available |
|
Frame-mount configuration |
Available |
Specifications are based on Bosch's current AVENAR panel 2000 documentation.
The AVENAR panel 2000 uses a 7-inch colour WVGA display with 800 × 480 pixel resolution in the current datasheet. The operator interface includes six keys and 18 LEDs for system indication and control.
This display provides the operator with a central interface for monitoring fire alarms, faults and other system events.
One of the main advantages of the AVENAR panel 2000 is its modular architecture.
The panel is supplied with a panel controller, power supply, battery controller module and one LSN loop module. Additional LSN 0300 A modules can be installed according to project requirements. Bosch specifies up to four additional loop modules.
This makes the panel suitable for projects where the required fire detection capacity may vary from a relatively small installation to a larger multi-loop system.
The AVENAR panel 2000 incorporates an Ethernet switch for panel networking and interfaces. Bosch also specifies network topologies based on CAN bus or Ethernet, depending on the system configuration.
Networking and management-system integration should be designed using the appropriate Bosch modules, software and system architecture rather than assuming that every interface is included in the base panel.
Bosch offers the AVENAR panel 2000 in different license and mounting configurations.
|
Model |
Configuration |
|
FPA-2000-SWM |
Standard license, wall-mount |
|
FPA-2000-PWM |
Premium license, wall-mount |
|
FPA-2000-SFM |
Standard license, frame-mount |
|
FPA-2000-PFM |
Premium license, frame-mount |
Bosch's product catalogue identifies these as the main AVENAR panel 2000 variants.
The AVENAR panel 2000 can be supplied in wall-mounted or frame-mounted configurations.
The published frame-mount panel kit dimension is approximately 638 × 450 × 232 mm. Battery requirements also differ between wall-mounted and frame-mounted configurations.
For a product quotation, DNG should specify the exact FPA-2000 part number instead of simply quoting “AVENAR Panel 2000.”
Bosch AVENAR panel 2000 can be used in applications such as:
The final panel configuration, loop capacity and connected devices should always be determined through proper fire alarm system design and applicable local requirements.
The AVENAR panel 2000 forms part of the Bosch AVENAR fire alarm ecosystem and can be configured with compatible components such as:
For example, Bosch's IOP 0008 A provides electrically isolated input/output interfaces for AVENAR systems and uses plug-and-play connections.
Installation and commissioning should be performed by trained fire alarm professionals.
Before purchasing an AVENAR panel 2000, confirm:
This is particularly important because AVENAR panel 2000 is a product family rather than one fixed hardware configuration.
Bosch AVENAR panel 2000 is a compact modular addressable fire alarm control panel designed for small and medium-sized fire detection systems.
The panel comes standard with one LSN loop module and can be expanded with up to four additional LSN 0300 A modules, giving a maximum configured architecture of five LSN loops.
Bosch specifies up to 254 LSN elements per loop. Actual project capacity depends on the system design and connected devices.
Yes. It is an addressable fire alarm panel using Bosch LSN technology. Bosch describes the AVENAR platform as a modular addressable fire alarm system.
FPA-2000-PWM is the Bosch AVENAR panel 2000 Premium License, Wall-Mount panel kit.
Both are wall-mounted AVENAR panel 2000 variants; SWM is the Standard License version and PWM is the Premium License version.
The current Bosch datasheet specifies a 7-inch colour WVGA display with 800 × 480 pixels.
Dispatch Time: Orders are typically processed and dispatched within 24-48 working hours upon successful payment confirmation via our secure gateway.
Delivery: We offer Pan-India delivery via secure logistics partners. Transit time is generally 3-7 business days depending on the location.
Returns: Defective items can be returned or exchanged within 7 days of delivery subject to our standard inspection and return policy. Please contact our support team to initiate a return request.